ABB INVERTER MICRO DRIVES ACS355 SUPPLY REFURBISHED and REPAIR SERVICES

24 Sep 2026
ABB INVERTER MICRO DRIVES ACS355 SUPPLY REFURBISHED and REPAIR SERVICES
View Full Size
ABB INVERTER MICRO DRIVES ACS355 SUPPLY REFURBISHED and REPAIR SERVICES

Ratings and types

Ratings IP20/UL Open

type/ NEMA 1 option

Type designation Frame

size

IP20

Frame

size

IP66

PN

(kW)

PN

(hp)

I2N

(A)

1-phase AC supply, 200 to 240 V +B063

0.37 0.5 2.4 ACS355-01X-02A4-2 R0-

0.75 1.0 4.7 ACS355-01X-04A7-2 R1-

1.1 1.5 6.7 ACS355-01X-06A7-2 R1-

1.5 2.0 7.5 ACS355-01X-07A5-2 R2-

2.2 3.0 9.8 ACS355-01X-09A8-2 R2-

3-phase AC supply, 200 to 240 V +B063

0.37 0.5 2.4 ACS355-03X-02A4-2 R0 R1

0.55 0.75 3.5 ACS355-03X-03A5-2 R0 R1

0.75 1.0 4.7 ACS355-03X-04A7-2 R1 R1

1.1 1.5 6.7 ACS355-03X-06A7-2 R1 R1

1.5 2.0 7.5 ACS355-03X-07A5-2 R1 R1

2.2 3.0 9.8 ACS355-03X-09A8-2 R2 R3

3.0 3.0 13.3 ACS355-03X-13A3-2 R2 R3

4.0 5.0 17.6 ACS355-03X-17A6-2 R2 R3

5.5 7.5 24.4 ACS355-03X-24A4-2 R3-

7.5 10.0 31.0 ACS355-03X-31A0-2 R4-

11.0 15.0 46.2 ACS355-03X-46A2-2 R4-

3-phase AC supply, 380 to 480 V +B063

0.37 0.5 1.2 ACS355-03X-01A2-4 R0 R1

0.55 0.75 1.9 ACS355-03X-01A9-4 R0 R1

0.75 1.0 2.4 ACS355-03X-02A4-4 R1 R1

1.1 1.5 3.3 ACS355-03X-03A3-4 R1 R1

1.5 2.0 4.1 ACS355-03X-04A1-4 R1 R1

2.2 3.0 5.6 ACS355-03X-05A6-4 R1 R1

3.0 3.0 7.3 ACS355-03X-07A3-4 R1 R1

4.0 5.0 8.8 ACS355-03X-08A8-4 R1 R1

5.5 7.5 12.5 ACS355-03X-12A5-4 R3 R3

7.5 10.0 15.6 ACS355-03X-15A6-4 R3 R3

11.0 15.0 23.1 ACS355-03X-23A1-4 R3-

15.0 20.0 31.0 ACS355-03X-31A0-4 R4-

18.5 25.0 38.0 ACS355-03X-38A0-4 R4-

22.0 30.0 44.0 ACS355-03X-44A0-4 R4-

X within the type designation stands for E or U.

PN for kW = Typical motor power in 400 V at normal use

PN for hp = Typical motor power in 460 V at normal use

I2N for A = Continuous rms current. 50% overload is allowed for

one minute in ten minutes.

Type designation

This is the unique reference number (shown in

column 4, right) that clearly identifies your drive

by current rating and frame size. Once the drive’s

type designation has been selected, the frame

size (column 5) can be used to determine the

drive dimensions, shown on page 12.

Voltages

ACS355 is available in two voltage ranges:

2 = 200 to 240 V

4 = 380 to 480 V

Insert either “2” or “4”, depending on your chosen

construction, current rating, voltage, and option

and variant codes into the type designation.

Current rating

Current rating represents the rated continuous

drive output current inside the drive

specification. Motor power stated in the table

below states the typical motor power.

Variant code

This code states the factory installed SW variants

to the drive. See pages 16 - 19 for details.

Construction

“01E” within the type designation varies

depending on the drive phase and EMC filtering.

Choose below the one you need.

01 = 1-phase

03 = 3-phase

E = EMC filter connected, 50 Hz frequency

U = EMC filter disconnected, 60 Hz frequency

(In case the fi lter is required it can easily

be connected


Cooling and fuses

Cooling

ACS355 is fitted with cooling fans as standard. The cooling

air must be free from corrosive substances and must not be

above the maximum ambient temperature of 40 °C (50 °C

with derating). Heat dissipation from IP66/IP67/UL Type 4X

drive equals to the IP20 UL Open values. For more specific

limits see the Technical specification – Environmental limits

in this catalog.

Cooling air flow

Type designation Frame

size

Heat dissipation Air flow

(W) BTU/hr1) m

3/h ft3/min

1-phase AC supply, 200 to 240 V

2)

ACS355-01X-02A4-2 R0 48 163 –

3-phase AC supply, 200 to 240 V

2)

–

ACS355-01X-04A7-2 R1 72 247 24 14

ACS355-01X-06A7-2 R1 97 333 24 14

ACS355-01X-07A5-2 R2 101 343 21 12

ACS355-01X-09A8-2 R2 124 422 21 12

2)

ACS355-03X-02A4-2 R0 42 142 –

2)

ACS355-03X-03A5-2 R0 54 183 –

3-phase AC supply, 380 to 480 V

2)

–

2)

–

ACS355-03X-04A7-2 R1 64 220 24 14

ACS355-03X-06A7-2 R1 86 295 24 14

ACS355-03X-07A5-2 R1 88 302 21 12

ACS355-03X-09A8-2 R2 111 377 21 12

ACS355-03X-13A3-2 R2 140 476 52 31

ACS355-03X-17A6-2 R2 180 613 52 31

ACS355-03X-24A4-2 R3 285 975 71 42

ACS355-03X-31A0-2 R4 328 1119 96 57

ACS355-03X-46A2-2 R4 488 1666 96 57

2)

ACS355-03X-01A2-4 R0 35 121 –

2)

ACS355-03X-01A9-4 R0 40 138 –

X within the type designation stands for E or U.

1) BTU/hr = British Thermal Unit per hour. BTU/hr is

approximately 0.293 Watts.

2) Frame size R0 with free convection cooling.

2)

–

2)

–

ACS355-03X-02A4-4 R1 50 170 13 8

ACS355-03X-03A3-4 R1 60 204 13 8

ACS355-03X-04A1-4 R1 69 235 13 8

ACS355-03X-05A6-4 R1 90 306 19 11

ACS355-03X-07A3-4 R1 107 364 24 14

ACS355-03X-08A8-4 R1 127 433 24 14

ACS355-03X-12A5-4 R3 161 551 52 31

ACS355-03X-15A6-4 R3 204 697 52 31

ACS355-03X-23A1-4 R3 301 1029 71 42

ACS355-03X-31A0-4 R4 408 1393 96 57

ACS355-03X-38A0-4 R4 498 1700 96 57

ACS355-03X-44A0-4 R4 588 2007 96 57

Free space requirements

Enclosure type Space above

(mm)

Space below

(mm)

Space on left/right

(mm)

All frame sizes 75 75 0

IP66/67 enclosure 75 75 20

Fuses

Standard fuses can be used with ABB machinery drives.

For input fuse connections see table below. Also Manual

Motor Protectors can be used to protect the installation.

See user’s manual for details.

Selection table

Type designation Frame

size

IEC fuses UL fuses

(A)

Fuse

type*) (A)

Fuse

type*)

1-phase AC supply, 200 to 240 V

ACS355-01X-02A4-2 R0 10 gG 10 UL class T

ACS355-01X-04A7-2 R1 16 gG 20 UL class T

ACS355-01X-06A7-2 R1 16/20 1) gG 25 UL class T

ACS355-01X-07A5-2 R2 20/25 1) gG 30 UL class T

ACS355-01X-09A8-2 R2 25/35 1) gG 35 UL class T

3-phase AC supply, 200 to 240 V

ACS355-03X-02A4-2 R0 10 gG 10 UL class T

ACS355-03X-03A5-2 R0 10 gG 10 UL class T

ACS355-03X-04A7-2 R1 10 gG 15 UL class T

ACS355-03X-06A7-2 R1 16 gG 15 UL class T

ACS355-03X-07A5-2 R1 16 gG 15 UL class T

ACS355-03X-09A8-2 R2 16 gG 20 UL class T

ACS355-03X-13A3-2 R2 25 gG 30 UL class T

ACS355-03X-17A6-2 R2 25 gG 35 UL class T

ACS355-03X-24A4-2 R3 63 gG 60 UL class T

ACS355-03X-31A0-2 R4 80 gG 80 UL class T

ACS355-03X-46A2-2 R4 100 gG 100 UL class T

3-phase AC supply, 380 to 480 V

ACS355-03X-01A2-4 R0 10 gG 10 UL class T

ACS355-03X-01A9-4 R0 10 gG 10 UL class T

ACS355-03X-02A4-4 R1 10 gG 10 UL class T

ACS355-03X-03A3-4 R1 10 gG 10 UL class T

ACS355-03X-04A1-4 R1 16 gG 15 UL class T

ACS355-03X-05A6-4 R1 16 gG 15 UL class T

ACS355-03X-07A3-4 R1 16 gG 20 UL class T

ACS355-03X-08A8-4 R1 20 gG 25 UL class T

ACS355-03X-12A5-4 R3 25 gG 30 UL class T

ACS355-03X-15A6-4 R3 35 gG 35 UL class T

ACS355-03X-23A1-4 R3 50 gG 50 UL class T

ACS355-03X-31A0-4 R4 80 gG 80 UL class T

ACS355-03X-38A0-4 R4 100 gG 100 UL class T

ACS355-03X-44A0-4 R4 100 gG 100 UL class T

X within the type designation stands for E or U.

*) According to IEC-60269 standard.

1) If 50% overload capacity is needed, use the bigger fuse alternative.
 